categories
  • Orthopaedic Cast Padding manufacturer
    Orthopaedic Wadding/Orthopaedic Cast Padding
    Orthopaedic Wadding/Orthopaedic Cast Padding
    These fillers are composed of high-quality cotton fibers that provide a soft environment under hard castings, prevent pressure points and minimize dimensional changes (causing the filler to move). It is placed on top of long pile paper and is suitable for use with all casting materials.
  • Ticare Tubular Bandage With Middle Line Blue/Green
    Ticare Tubular Bandage With Middle Line
    Tubular Bandage, best used in the retention of all types of wound/ointment dressing pads without using tape. Allows for fast and easy dressing changing and inspection during healing process.
  • Ticare Orthopaedic Fiberglass Casting Tape Wholesale
    Ticare Orthopaedic Fiberglass Casting Tape
    Whether cast or splinted, they usually require fiberglass casts because the injured limb needs all the support they can get. Our orthopaedic medical plaster supplies are the perfect solution for medical applications or even artistic hobby use.
  • Disposable Infusion Set for Pediatric from Ticare Health
    Pediatric Infusion Set
    Professional custom TICARE® HEALTH Microdrop infusion sets for pediatric online OEM&ODM. Enables more accurate delivery of small infusions (60 drops/ml) to neonatal or infant patients. Configuration: ABS plastic needle, PVC tube, float valve, tube length 150cm, ABS/PE regulator, 150/100ml dropper bottle (soft bottle/hard bottle), with Y-connector, socket/screw, with needle or without Needle.
  • TICARE® AED Automated External Defibrillators Wholesale
    TICARE® I Type Automated External Defibrillators (AEDs)
    TICARE® I Type Automated External Defibrillators (AEDs)
    Automatic external defibrillator (AED) is a portable life-saving device, which is used to treat patients with cardiac arrest, which is a disease in which the heart suddenly and unexpectedly stops beating.
  • TICARE® Automated External Defibrillators (AEDs) Professional
    TICARE® II Type Automated External Defibrillators (AEDs)
    Display Screen Type: High-resolution display Screen Size: 8 inch Languages: 5 to Choose Sweep Speed: 25mm/sec Information: Heart Rate, Lead/Pads, Alarm, On/Off, SpO2, AED Functions and Prompts Alarm Selection and Limits Delivered Energy 5 Languages available: English/Russian/Spanesh/Chinese/Turkish Defibrillator Waveform: Biphasic Charge Time: Less than 7 seconds with a new fully charged battery Energy Display: Monitor display indicates both selected and delivered energy Charge Prompt Type: Voice and visual prompts Electrode Impedance Measurement Range: 0-250 ohms. ECG Monitoring Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles Lead Selection: Displayed on monitor paddles III lI AVR AVL AVF V ECG Size: 0.25/0.5/1/1.5/24 cm/mV display on monitor Heart Rate: 20-300BPM Heart Rate Alarm: On/Off displayed on monitor user-selectable Smart Alarms: Beeper/voice prompts indicate shock able rhythm. Battery Type: Rechargeable Ni-MH battery 12V Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. Sp02 Module [Options] Measurement Range: 30~100%±2% between 80%~90% others±5% Alarm Range: User set high limit and low limit Alarm Accuracy:±10% within setting values Alarm time Accuracy: less than 12 sec 1-Meditech Pulse Oximeter 2-Nellcor Pulse Oximeter Pacemaker Type: VVI Pulse Type: rectangular,constant current Pulse Amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater). Pacing Rate: Variable from 30 ppm to 180 ppm±1.5% (increments or decrements by a value of 2 ppm) Multi-Function Electrode: (MFE) Pads: multipurpose defibrillation/pacing electrodes Pause: Pacing pulse frequency reduced by a factor of 4 when activated Refractory Period: NC(WI demand do not have this specification) Pulse Width: (20+1.5 ms) Output Protection: Fully defibrillator protected and isolated Recorder Paper: 50mm thermal. Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay. Printing Method: High-resolution thermal print head. Print-out Modes: Manual or automatic user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. AED Mode AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts. Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >= 140bpm and QRS complex wave duration >=1 40ms. Charge Control: Control on device front panel press key on paddle. Prompts: Voice and visual prompts. Manual Mode Energy Selection: Selectable at 25710 20 30 50 70100 150 200 300 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor. Recommended Products 1. TICARE® I Type Automated External Defibrillators 2. TICARE® Chest Drainage System 1 Chamber
1 2

A total of 2 pages

Send A Message
Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact