Diagnostic Supplies
categories

TICARE® White Tubing Dual Head Stethoscope

A stethoscope with white tubing, it helps healthcare professionals assess a patient's heartbeat, breathing, and digestive sounds for diagnostic purposes.
  • Item no.:

    TC1073-3
  • Product origin:

    China
  • Shipping port:

    Shanghai/Guangzhou/Xiamen
  • Brand:

    Ticare®
  • Product Detail

Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products

As a professionai Supplier In China, We always endeavor to further improve product quality in order to better user's life standard.

White Tube Gold Stethoscope - TICARE® HEALTH
TICARE® White Tube Gold Stethoscope

A stethoscope with white tubing, it helps healthcare professionals assess a patient's heartbeat, breathing, and digestive sounds for diagnostic purposes.

Deluxe White Stethoscope - TICARE® HEALTH
TICARE® Deluxe White Stethoscope

A stethoscope with white tubing, it helps healthcare professionals assess a patient's heartbeat, breathing, and digestive sounds for diagnostic purposes.

Padded Wood Board Splints - TICARE HEALTH
TICARE® Padded Wood Board Splints

The TICARE® Padded Wood Board Splints provide a reliable and comfortable solution for immobilizing and supporting injured limbs. Their durable construction, padded design, and ease of use make them an essential tool for emergency responders, healthcare professionals, and anyone involved in first-aid care.

TICARE® Automated External Defibrillators (AEDs) Professional
TICARE® II Type Automated External Defibrillators (AEDs)

Display Screen Type: High-resolution display Screen Size: 8 inch Languages: 5 to Choose Sweep Speed: 25mm/sec Information: Heart Rate, Lead/Pads, Alarm, On/Off, SpO2, AED Functions and Prompts Alarm Selection and Limits Delivered Energy 5 Languages available: English/Russian/Spanesh/Chinese/Turkish Defibrillator Waveform: Biphasic Charge Time: Less than 7 seconds with a new fully charged battery Energy Display: Monitor display indicates both selected and delivered energy Charge Prompt Type: Voice and visual prompts Electrode Impedance Measurement Range: 0-250 ohms. ECG Monitoring Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles Lead Selection: Displayed on monitor paddles III lI AVR AVL AVF V ECG Size: 0.25/0.5/1/1.5/24 cm/mV display on monitor Heart Rate: 20-300BPM Heart Rate Alarm: On/Off displayed on monitor user-selectable Smart Alarms: Beeper/voice prompts indicate shock able rhythm. Battery Type: Rechargeable Ni-MH battery 12V Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. Sp02 Module [Options] Measurement Range: 30~100%±2% between 80%~90% others±5% Alarm Range: User set high limit and low limit Alarm Accuracy:±10% within setting values Alarm time Accuracy: less than 12 sec 1-Meditech Pulse Oximeter 2-Nellcor Pulse Oximeter Pacemaker Type: VVI Pulse Type: rectangular,constant current Pulse Amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater). Pacing Rate: Variable from 30 ppm to 180 ppm±1.5% (increments or decrements by a value of 2 ppm) Multi-Function Electrode: (MFE) Pads: multipurpose defibrillation/pacing electrodes Pause: Pacing pulse frequency reduced by a factor of 4 when activated Refractory Period: NC(WI demand do not have this specification) Pulse Width: (20+1.5 ms) Output Protection: Fully defibrillator protected and isolated Recorder Paper: 50mm thermal. Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay. Printing Method: High-resolution thermal print head. Print-out Modes: Manual or automatic user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. AED Mode AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts. Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >= 140bpm and QRS complex wave duration >=1 40ms. Charge Control: Control on device front panel press key on paddle. Prompts: Voice and visual prompts. Manual Mode Energy Selection: Selectable at 25710 20 30 50 70100 150 200 300 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor. Recommended Products 1. TICARE® I Type Automated External Defibrillators 2. TICARE® Chest Drainage System 1 Chamber

Two Function Electric Hospital Bed, TC-HB014 - TICARE® HEALTH
Two Function Electric Hospital Bed, TC-HB014

The functions of the two functional hospital beds are as follows: the overall bed body balance lift, back lift, leg flexion and extension, leg lift, etc.

10g Diabetes Filament Monofilament – Foot Sensation Testing Tool | Manufacturer & Wholesale
Diabetes Filament - 10g Monofilament for Foot Sensation Testing

The Diabetes Filament: 10g Monofilament is a reliable and easy-to-use tool designed for assessing foot sensation in individuals with diabetes. It is a vital instrument in the early detection and monitoring of diabetic peripheral neuropathy, a common complication that can lead to serious foot problems if left untreated.

TC/XSZ-2005 Biological Monocular Microscope - TICARE HEALTH
TICARE® TC/XSZ-2005 Biological Monocular Microscope

The TICARE® TC/XSZ-2005 Biological Monocular Microscope is a versatile and reliable instrument designed to meet the needs of students, educators, researchers, and professionals in various scientific fields. Its high-quality optics, robust construction, and user-friendly design make it an excellent choice for detailed biological observations and analyses.

Send A Message
Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact