products
categories

TICARE® Luxury Transfusion Chair

  • Item no.:

    TC9028
  • Product origin:

    China
  • Shipping port:

    Shanghai/Guangzhou/Xiamen
  • Brand:

    Ticare®
  • Product Detail
Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products

As a professionai Supplier In China, We always endeavor to further improve product quality in order to better user's life standard.

SiliconScrub Electrosurgical Tip Cleaner - TICARE HEALTH
SiliconScrub Electrosurgical Tip Cleaner

Effortlessly clean and maintain the performance of your electrosurgical tips with SiliconScrub Electrosurgical Tip Cleaner. This innovative solution ensures thorough and efficient cleaning, removing residue and maximizing tip longevity. Improve surgical precision and reduce downtime with this essential tool.

Ticare Gauze Pads 5 x 5 cm Non Sterile
Ticare Gauze Pads 5 x 5 cm

Super soft and super absorbent cotton, breathable, fast wicking action to suck liquid from the wound, protect the wound area and help improve the healing process, independent packaging

Ticare Self Adhesive Elastic Bandage 6 x 4.5 m Supply
Ticare Self Adhesive Elastic Bandage 6" x 4.5 m

Elastic bandages help hold the bandage in place, relieve swelling and promote healing, ideal for strains and sprains. A great addition to any First Aid Kit and daily use for skin regimens & wound care.

TICARE® Automated External Defibrillators (AEDs) Professional
TICARE® II Type Automated External Defibrillators (AEDs)

Display Screen Type: High-resolution display Screen Size: 8 inch Languages: 5 to Choose Sweep Speed: 25mm/sec Information: Heart Rate, Lead/Pads, Alarm, On/Off, SpO2, AED Functions and Prompts Alarm Selection and Limits Delivered Energy 5 Languages available: English/Russian/Spanesh/Chinese/Turkish Defibrillator Waveform: Biphasic Charge Time: Less than 7 seconds with a new fully charged battery Energy Display: Monitor display indicates both selected and delivered energy Charge Prompt Type: Voice and visual prompts Electrode Impedance Measurement Range: 0-250 ohms. ECG Monitoring Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles Lead Selection: Displayed on monitor paddles III lI AVR AVL AVF V ECG Size: 0.25/0.5/1/1.5/24 cm/mV display on monitor Heart Rate: 20-300BPM Heart Rate Alarm: On/Off displayed on monitor user-selectable Smart Alarms: Beeper/voice prompts indicate shock able rhythm. Battery Type: Rechargeable Ni-MH battery 12V Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. Sp02 Module [Options] Measurement Range: 30~100%±2% between 80%~90% others±5% Alarm Range: User set high limit and low limit Alarm Accuracy:±10% within setting values Alarm time Accuracy: less than 12 sec 1-Meditech Pulse Oximeter 2-Nellcor Pulse Oximeter Pacemaker Type: VVI Pulse Type: rectangular,constant current Pulse Amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater). Pacing Rate: Variable from 30 ppm to 180 ppm±1.5% (increments or decrements by a value of 2 ppm) Multi-Function Electrode: (MFE) Pads: multipurpose defibrillation/pacing electrodes Pause: Pacing pulse frequency reduced by a factor of 4 when activated Refractory Period: NC(WI demand do not have this specification) Pulse Width: (20+1.5 ms) Output Protection: Fully defibrillator protected and isolated Recorder Paper: 50mm thermal. Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay. Printing Method: High-resolution thermal print head. Print-out Modes: Manual or automatic user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. AED Mode AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts. Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >= 140bpm and QRS complex wave duration >=1 40ms. Charge Control: Control on device front panel press key on paddle. Prompts: Voice and visual prompts. Manual Mode Energy Selection: Selectable at 25710 20 30 50 70100 150 200 300 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor. Recommended Products 1. TICARE® I Type Automated External Defibrillators 2. TICARE® Chest Drainage System 1 Chamber

Send A Message
Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact